Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A

Zhejiang KRIPAL Electric Co., Ltd.
Contact Now

Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A

Brand Name : KRIPAL

Model Number : UKL1

Certification : CE

Place of Origin : China

MOQ : 1000 pcs

Price : negotiable

Payment Terms : T/T, L/C

Supply Ability : 200000 pcs per month

Delivery Time : 20 days and depends on ordering quantity

Packaging Details : 12 poles packed in one small box and then in carton

Poles available : 2P, 4P

Ampere : 16A 25A 40A 63A

Residual protection : Yes

Type : mini circuit breaker

leakage current : 10 30 100 300 500mA

Standard : IEC1008 EN61008

Contact Now

Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A


KRIPAL has the design patent for these items


A residual-current device (RCD), or residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly enough to prevent injury caused by such shocks. They are not intended to provide protection against overcurrent (overload) or all short-circuit conditions.

Techinical data:


A. Conform to standard: GB16916.1
B. Rated voltage (Ue): 230V/400V; 50/60Hz
C. Rated current (A): 16, 25, 40, 63 A (2 poles and 4poles)
D. Rated leakage current: 10, 30, 100, 300, 500Ma
E. Electric life: ≥ 4000 times (on-off)
F. Mechanical life: ≥ 2000 times (on-off)
G. Case protection grade: IP40 after installing


Mechanical parameter

A. Installation mode: At the DIN rail of standard IEC
B. Terminal wiring capability: Conductor 1-25 mm
C. Width of shell: 2 poles 36mm; 4 poles 72 mm


Main characteristic

A. Various current specifications of leakage action ca easily ensure selective protection.
B. Inaccurate action resulting form the switch operation of electronic equipment can be avoided
C. Unless specified otherwise, the width of two-poles switch is two modules, four-poles(3P+N) is four modules


Specifications:

Technology Specification & Electrical Specification
Electric standard IEC1008 EN61008
Trip time Non-time delay; Minimal 10ms time delay
Rated voltage 230V/400V
Rated surplus operating current 10; 30; 100; 300mA, 500mA
Selection grade 3
Poles 2pole 4pole
Rated current 16A, 25A, 40A, 63A
Tripping character B, C, D characteristic curve
Terminal wiring conductor 1-25 mm2
Environment capability According to the IEC 1008 standard
Case protection grade IP40 after installation
Electric life Not less than 4000 times of breaking and closing
Mechanical life Not less than 2000 times of breaking and closing
Mechanical Parameter
Installation mode Installation at the DIN guide rail of 35mm
Terminal block capacity General thickness 0.8-2mm



Main benefits:

High quality
Complete range


Instantaneous tripping current:

International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:

Type

Instantaneous tripping current

B

above 3 In up to and including 5 In

C

above 5 In up to and including 10 In

D

above 10 In up to and including 20 In


Product Tags:

small circuit breaker

      

micro circuit breaker

      
Best Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A wholesale

Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhejiang KRIPAL Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0